7.2.1 Main circuit power connection

The input power specification of the Delta robot controller is AC 200V to 230V single-phase 50/60 Hz.
Customers need to connect the main power manually and please use cables that comply with VW-1
flame resistance and UL758 wire diameter specifications, as well as cables with the specifications in
Table 7.1 below:

Table7. 1 Main circuit power specification table

Power control box main circuit power cable specifications
Power cable diameter
Ground cable diameter
Installation:
There is a forced interface behind the power control box for customers to install the cables for the
1.
main power circuit; the forced connector specifications are as shown in Table 7.2 below.

Table7. 2 Forced connector specification table

Forced connector allowable cable diameter
Please insert the power cable of the main circuit to this forced connector, as shown in Figure
2.
7.3 below.

Figure7. 3 Power cable penetrating the forced connector

Forced connector specifications
104
SCARA CE Series
2.0mm²
10mm²
14.5mm~19mm