Drs60L3 Series Active Hardware Point; Figure5. 9 Drs60L3 Series First Arm Active Point Position And The Various Operation Ranges; Table5. 7 Drs60L3 Series Point Screw Locking Torque - Delta SCARA DRS40L Series User Manual

Robot syetem
Table of Contents

Advertisement

Delta SCARA Robot System User Manual
SCARA CE Series

5.4 DRS60L3 series active hardware point

The installation position of the first arm active point of DRS60L3 series and the working angle are as
shown in Figure 5.9 below.
O
J1=108
(Active point)
O
J1=114
(Limit point)
O
J1=114
(Limit point)
O
J1=108
(Active point)
Figure5. 9
DRS60L3 series first arm active point position and the various operation ranges
Table 5.7 below is the first arm point screw and locking torque for DRS60L3 series installation.
Table5. 7
DRS60L3 series point screw locking torque
Name
Screw torque value
Remark
M6x12 hex socket screws +
Tools
#5 hex wrench
9.7 to 10.5 N-m
M6 spring washer