Figure7. 41 Safety Door Switch Figure; Figure7. 42 Electromagnetic Safety Switch Wiring - Delta SCARA DRS40L Series User Manual

Robot syetem
Table of Contents

Advertisement

Delta SCARA Robot System User Manual
For safety protection needs, users can install safety lock switches on the railings in order to ensure that
the safety door can close properly, as shown in Figure 7.41 below.
A safer practice is to select electromagnetic safety door switches so that when the safety door is closed,
the safety switch will generate magnetic force to keep the door lock bolt securely in place and prevent
users from accidentally opening the door and entering the railing, causing danger.
The power switch of the electromagnetic safety door lock can be installed inside the railing so that when
workers are accidentally trapped inside the railing, they only need to turn off the power switch to release
and electromagnetic safety door and save themselves. The installation method is as shown in Figure
7.42 below.

Figure7. 41 Safety door switch figure

Figure7. 42 Electromagnetic safety switch wiring

130
Safety door lock power switch
installed inside the railing
-
SCARA CE Series
+