Table11. 2 Fuse Replacement Steps - Delta SCARA DRS40L Series User Manual

Robot syetem
Table of Contents

Advertisement

Delta SCARA Robot System User Manual
Solution:
If the malfunction status above occurred, it might be due to the corresponding fuse being burnt. Please
open the power control box door to check the fuse circuit and perform replacement if necessary. Please
make sure to wait for 10 minutes after the power has been turned off before opening the power control
box door to perform replacement operations in order to avoid residue voltages and getting electrical
shocks. Please refer to the processes in Table 11.2 below to perform the replacement.

Table11. 2 Fuse replacement steps

1. Open the power control box door and
find the corresponding fuse to perform
checking; there are labels on top of the
fuses that corresponds to the fuses.
3. Open the fuse seat cover when replacing
the fuse, and remove the fuse by moving
it from left to right, then install a fuse that
corresponds to the specifications listed
in Table 4-1.
2. Please use the ohm gear of a multimeter
to perform measurement of the fuse; if it
has an open circuit it means that the fuse
has been burnt and needs to be replaced.
4. Replace the fuse cover to complete the
replacement.
187
SCARA CE Series

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents