6.3.3 Initializing the Communications Settings

6.3.3

Initializing the Communications Settings

You use the communications setting switch (S1) to restore the Ethernet and MECHATROLINK-III communi-
cations settings to their factory settings.
• Type A01 SERVOPACK
• Type A02 SERVOPACK
Pin on S1
1
2
If you turn ON the communications initialization pin, the SERVOPACK will start with the following commu-
nications settings.
IP Address
Station Address
Number of Transmission Bytes
Note: Pn880, Pn881, and Pn030 are not initialized.
6-4
CN31
Communications setting switch (S1)
Function
OFF
Initializing the commu-
nications settings
ON
Reserved
OFF (Do not change.)
(Do not use.)
Parameter
CN32
OFF
ON
Normal mode (factory setting)
Initializes the communications settings.
192.168.1.1
0003H
0048
OFF
ON
1
2
1
2
Setting
Factory setting