YASKAWA E-V-MD Series User Manual page 255

Ac, rotational motor, mechatrolink-iii communications references, servomotor
Table of Contents

Advertisement

5.
Click Measurement complete.
6.
If setting the parameters to the values shown in the measurement results, click Result Writing.
(3) Related Parameters
The following parameters are either referenced or automatically changed during execution of EasyFFT.
Do not change the settings of these parameters from the SigmaWin+ or any other means during execution of
EasyFFT.
Parameter
Pn408
Torque Related Function Switch
Pn409
1st Notch Filter Frequency
Pn40A
1st Notch Filter Q Value
Pn40C
2nd Notch Filter Frequency
Pn40D
2nd Notch Filter Q Value
Pn456
Sweep Torque Reference Amplitude
Name
9.13 EasyFFT
Automatic
changes
Yes
Yes
No
Yes
No
No
9