11 Appendix
11.2.1 List of Parameters
Parameter
Size
No.
Input Signal Selection
2
(P-OT Signal Assignment)
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn590
Input Signal Selection
2
(N-OT Signal Assignment)
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn591
11-14
Setting
Name
Range
0000 to
2007
P-OT Signal Pin Number Assignment
0
Selects sequence input signal /SI-0.
1
Selects sequence input signal /SI-1.
2
Selects sequence input signal /SI-2.
3
Selects sequence input signal /SI-3.
4
Selects sequence input signal /SI-4.
5
Selects sequence input signal /SI-5.
6
Selects sequence input signal /SI-6.
7
Selects sequence input signal /SI-7.
Reserved (Do not change.)
Reserved (Do not change.)
P-OT Signal Assignment Selection
0
P-OT signal assignment disabled. [factory setting]
1
P-OT signal assigned. Positive drive is enabled when the signal is low.
2
P-OT signal assigned. Positive drive is enabled when the signal is high.
0000 to
2007
N-OT Signal Pin Number Assignment
0
Selects sequence input signal /SI-0.
1
Selects sequence input signal /SI-1.
2
Selects sequence input signal /SI-2.
3
Selects sequence input signal /SI-3.
4
Selects sequence input signal /SI-4.
5
Selects sequence input signal /SI-5.
6
Selects sequence input signal /SI-6.
7
Selects sequence input signal /SI-7.
Reserved (Do not change.)
Reserved (Do not change.)
N-OT Signal Assignment Selection
0
N-OT signal assignment disabled. [factory setting]
1
N-OT signal assigned. Reverse drive is enabled when the signal is low.
2
N-OT signal assigned. Reverse drive is enabled when the signal is high.
Factory
When
Units
Setting
Enabled
–
0000
After restart
–
0000
After restart
(cont'd)
Reference
Classification Profile
Section
−
Setup
Reference
Section
7.3.2
Reference
Section
7.3.2
−
Setup
Reference
Section
7.3.2
Reference
Section
7.3.2
–
–