11 Appendix
11.2.1 List of Parameters
Parameter
Size
No.
Input Signal Selection
2
(/EXT2 Signal Assignment)
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn594
Input Signal Selection
2
(/EXT3 Signal Assignment)
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn595
11-16
Setting
Name
Range
0000 to
2007
/EXT2 Signal Pin Number Assignment
0
Selects sequence input signal /SI-0.
1
Selects sequence input signal /SI-1.
2
Selects sequence input signal /SI-2.
3
Selects sequence input signal /SI-3.
4
Selects sequence input signal /SI-4.
5
Selects sequence input signal /SI-5.
6
Selects sequence input signal /SI-6.
7
Selects sequence input signal /SI-7.
Reserved (Do not change.)
Reserved (Do not change.)
/EXT2 Signal Assignment Selection
0
/EXT2 signal assignment disabled. [factory setting]
1
/EXT2 signal assigned. Signal is ON for low level.
2
/EXT2 signal assigned. Signal is ON for high level.
0000 to
2007
/EXT3 Signal Pin Number Assignment
0
Selects sequence input signal /SI-0.
1
Selects sequence input signal /SI-1.
2
Selects sequence input signal /SI-2.
3
Selects sequence input signal /SI-3.
4
Selects sequence input signal /SI-4.
5
Selects sequence input signal /SI-5.
6
Selects sequence input signal /SI-6.
7
Selects sequence input signal /SI-7.
Reserved (Do not change.)
Reserved (Do not change.)
/EXT3 Signal Assignment Selection
0
/EXT3 signal assignment disabled. [factory setting]
1
/EXT3 signal assigned. Signal is ON for low level.
2
/EXT3 signal assigned. Signal is ON for high level.
Factory
When
Units
Setting
Enabled
−
0000
After restart
−
0000
After restart
(cont'd)
Reference
Classification Profile
Section
−
Setup
−
Setup
−
−