8 Adjustments
8.7.2 Vibration Suppression Function Operating Procedure
7.
Set a frequency by using the Import function or by manually selecting the frequency.
Click Import. The value of the residual vibration frequency being monitored will be imported to the Set
frequency box. This function, however, is effective only when the residual vibration frequency is
between 1.0 and 100.0.
The Set frequency can be manually selected by clicking the setting arrows.
8.
Click Set.
If any vibration still occurs, manually make fine adjustments to the Set frequency, and click Set.
If you need to undo the change you made while making adjustments, click Reset. The setting will be
restored to the original value.