(4) Brake Signal (/BK) Output Timing during Servomotor Rotation
If an alarm occurs while the servomotor is rotating, the servomotor will come to a stop and the brake signal
(/BK) will be turned OFF. The timing of brake signal (/BK) output can be adjusted by setting the brake refer-
ence output speed level (Pn507) and the waiting time for brake signal when motor running (Pn508).
Note: If the servomotor is set so that it comes to a zero-speed stop for an alarm, follow the information in (3) Brake ON
Timing after the Servomotor Stops after the servomotor comes to a stop for a zero position reference.
Brake Reference Output Speed Level
Pn507
Setting Range
0 to 10000
Waiting Time for Brake Signal When Motor Running
Pn508
Setting Range
10 to 100
/BK Signal Output Conditions
When Servomotor Rotating
The /BK signal goes to high level
(brake ON) when either of the fol-
lowing conditions is satisfied:
• When the motor speed falls
below the level set in Pn507
after the power to the servomo-
tor is turned OFF.
• When the time set in Pn508 is
exceeded after the power to the
servomotor is turned OFF.
Setting Unit
-1
1 min
Setting Unit
10 ms
SV_OFF
command
or alarm or
power OFF
Motor speed
Power to motor
/BK output
• The servomotor will be limited to its maximum speed even if the value set in Pn507 is
higher than the maximum speed.
Speed
Position
 
Factory Setting
When Enabled
100
Immediately
Speed
Position
 
Factory Setting
When Enabled
50
Immediately
Servo OFF
Servo ON
Motor stopped by
Pn-507
coasting Pn001.0
OFF
ON
Brake
released
Brake applied
(OFF)
(ON)
Pn508