12.5.3

Analog inputs

Signal processing using the analog inputs is shown in the function diagrams listed below.
Properties
● Hardware input filter set permanently
● Simulation mode parameterizable
● Adjustable offset
● Signal can be inverted via binector input
● Adjustable absolute-value generation
● Noise suppression (p4068)
● Enabling of inputs via binector input
● Output signal available via connector output
● Scaling
● Smoothing
Note
Parameters p4057 to p4060 of the scaling do not limit the voltage values / current values (for
TM31, the input can be used as current input).
Analog input of Control Unit 310-2
Control Unit CU310-2 has an integrated analog input at terminal strip X131, terminals 7 and
8, an analog input. The input is preset as current or voltage input using DIP switch S5. The
input can be further differentiated using p0756 [x]:
The characteristic of the analog input can be scaled using parameters p0757 to P0760.
The value of the analog input can be read out from r0755.
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
p0756[x]
Input function
0
0 ... 10 V
2
0 ... 20 mA
3
4 ... 20 mA
4
-10 V ... + 10 V
5
-20 mA ... + 20 mA