12.8

Examples of replacing components

Note
To ensure that the entire functionality of a firmware version can be used, it is recommended
that all the components in a drive line-up have the same firmware version.
Description
If the type of comparison is set to the highest setting, the following examples apply.
A distinction is made between the following scenarios:
● Component with a different order number
● Components with an identical order number
When p9909 = 1, the serial number and the hardware version of the new replacement
component are automatically transferred from the actual topology to the reference topology,
and then saved in the non-volatile memory.
When p9909 = 0, serial numbers and hardware versions are not automatically transferred. In
this case, when the data in the electronic rating plate match, the transfer is realized using
p9904 = 1 or p9905 = 1.
For the components that have been replaced, the electronic rating plate must match as far
as the following data is concerned:
● Component type (e.g. "SMC20")
● Order No. (e.g. "6SL3055–0AA00–5Bxx")
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
– Topology comparison component replacement active (p9909 = 1)
– Topology comparison component replacement inactive (p9909 = 0)
Basic information about the drive system
12.8 Examples of replacing components
881