Redundant Data Backup On Memory Card - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic information about the drive system
12.6 Data backup
Note
NVRAM and know-how protection
Know-how protection and write protection apply to parameter p7775. If the parameter should
be readable despite activated protection mechanisms, then p7775 must be placed in the
exception list.
Note
NVRAM and write protection
When write protection is activated, p7775 can only be written to from a higher-level controller
using cyclic communication.
More information on fault buffers, diagnostic buffers and message buffers is provided in the
SINAMICS S120 Commissioning Manual.
12.6.2

Redundant data backup on memory card

In conjunction with the "Firmware download via Web server" and the associated remote
access, the "Redundant data backup on memory card" provides safe access again to the
device in the event of an interruption of the connection or the power supply. This redundant
data backup cannot be deactivated.
As of firmware version V4.6, the memory cards have a backup partition in addition to the
normal working partition. The most important data is duplicated on this backup partition
during ramp-up of the CU. This ensures that when you update the data on the memory card
a data loss cannot occur due to a power failure. Only the system can access this backup
partition. The partition is not visible for users.
If damage to the file system is detected on the memory card, the system reconstructs the
data on the working partition from the backup partition at the next ramp-up of the CU. In this
case, the fault "F01072: Memory card restored from backup copy" is output. A running
restoration of the data is indicated via the LEDs (FW Loading). Generally, the restoration of
the data takes one minute.
The duplication of changed project data on the backup partition takes just a few seconds
during ramp-up. After write operations on the working partition (e.g. RAM to ROM), the
system automatically recognizes when an update of the backup copy on the backup partition
is required and issues the message "A01073: POWER ON required for backup copy on
memory card". In this case, perform a POWER ON for the Control Unit or a hardware reset
(via p0972).
868
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Drive functions

Advertisement

Table of Contents
loading

Table of Contents