9.5 Safe Stop 1 (SS1, time controlled)
Differences between "Safe Stop 1 (time-controlled) with OFF3 and with external stop"
With external stop, "Safe Stop 1 (time-controlled)" functions in principle exactly the same
way as described in the previous Section "Safe Stop 1 (time-controlled) with OFF3". Note,
however, the following differences:
● In order to activate "Safe Stop 1 (time controlled) with external stop", additionally set
● When SS1 is selected, the drive is not braked along the OFF3 ramp, but after the delay
9.5.3

Function diagrams and parameters

Function diagrams (see SINAMICS S120/S150 List Manual)
• 2810
• 2811
580
p9653 to 1.
time has expired (p9652/p9852), only STO/SBC is automatically initiated. After the
function has been selected, the delay timer runs down - even if the function is deselected
during this time. In this case, after the delay time has expired, the STO/SBC function is
selected and then again deselected immediately.
SI Basic Functions - STO (Safe Torque Off), SS1 (Safe Stop 1)
SI Basic Functions - STO (Safe Torque Off), safe pulse cancellation
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3