4.9 Torque limiting

4.9
Torque limiting
Description
The torque limiting value specifies the maximum permissible torque. Different limits can be
parameterized for motoring and generating operation.
● p0640[0...n] Current limit
● p1520[0...n] CO: Torque limit, upper/motoring
● p1521[0...n] CO: Torque limit, lower/regenerative
● p1522[0...n] CI: Torque limit, upper/motoring
● p1523[0...n] CI: Torque limit, lower/regenerative
● p1524[0...n] CO: Torque limit, upper/motoring, scaling
● p1525[0...n] CO: Torque limit, lower/regenerative scaling
● p1530[0...n] Motor mode power limit
● p1531[0...n] Regenerative mode power limit
Figure 4-14
The currently active torque limit values are displayed in the following parameters:
● r0067 Maximum drive output current
● r1526 Torque limit, upper/motoring without offset
● r1527 Torque limit, lower/regenerative without offset
All of the following limits apply to the torque setpoint, which is present either at the speed
controller output in the case of speed control, or at the torque input in the case of torque
control. The minimum/maximum value of the different limits is used in each case. The
minimum value is calculated cyclically and displayed in parameters r1538 and r1539:
● r1538 CO: Upper effective torque limit
● r1539 CO: Lower effective torque limit