Infeed
1.3 Basic Infeed
Switching off the Basic Line Module
For switching off, carry out the steps for switching on in the reverse order. However, there is
no pre-charging at switch off.
Control and status messages
Table 1- 7
Basic Infeed open-loop control
Signal name
ON/OFF1
OC/OFF2
Acknowledge fault
Master control by PLC
Table 1- 8
Basic Infeed status message
Signal name
Ready to start
Ready
Operation enabled
Fault active
No OFF2 active
Switching on inhibited
Alarm active
Control requested
Pre-charging completed
Line contactor closed
52
Internal
Binector input
control word
STWAE.0
p0840 BI: ON/OFF1
STWAE.1
p0844 BI: 1st OFF2 and
p0845 BI: 2nd OFF2
STWAE.7
p2103 BI: 1st acknowledge faults or
p2104 BI: 2nd acknowledge faults or
p2105 BI: 3rd acknowledge faults
STWAE.10
p0854 BI: Master control by PLC
Internal status word
ZSWAE.0
ZSWAE.1
ZSWAE.2
ZSWAE.3
ZSWAE.4
ZSWAE.6
ZSWAE.7
ZSWAE.9
ZSWAE.11
ZSWAE.12
Display of internal
control word
r0898.0
r0898.1
r2138.7
r0898.10
Parameter
r0899.0
r0899.1
r0899.2
r2139.3
r0899.4
r0899.6
r2139.7
r0899.9
r0899.11
r0899.12
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
PROFIdrive
telegram 370
E_STW1.0
E_STW1.1
E_STW1.7
E_STW1.10
PROFIdrive telegram 370
E_ZSW1.0
E_ZSW1.1
E_ZSW1.2
E_ZSW1.3
E_ZSW1.4
E_ZSW1.6
E_ZSW1.7
E_ZSW1.9
E_ZSW1.11
E_ZSW1.12
Drive functions