Communication
10.2 Communication via PROFIBUS DP
7. In the first column, select the PROFIBUS DP address of the Publisher, in this example
8. The "I/O address" column displays the start address for every drive object.
748
"6".
All PROFIBUS DP slaves are listed here, for which actual value data can be retrieved. It
also provides the possibility of sharing data via slave-to-slave communication within the
same drive device.
Select the start address of the data of the drive object to be read. In the example, "268" is
proposed.
If the complete data of the Publisher are not to be read, set this using the "Length"
column. Alternatively, you can shift the start address of the access, so that the required
data can be read out from the center section of the telegram component of the drive
object.
Figure 10-32 Configuring the slave-to-slave communication nodes
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Drive functions