Scaling - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

12.4.6

Scaling

Signals for the analog outputs
Table 12- 5
Signal
Speed setpoint before the
setpoint filter
Actual speed value, motor
encoder
Actual speed value
Drive output frequency
Absolute actual current value
Actual DC-link voltage value
Total torque setpoint
Actual active power
Control deviation
Modulation depth
Torque-generating current
setpoint
Torque-generating actual
current value
Flux setpoint
Flux actual value
Speed controller
PI torque output
Speed controller
I torque output
Changing scaling parameters p2000 to p2007
Note
If a per unit representation is selected and the reference parameter is subsequently changed
(e.g. p2000), the per unit values of some control parameters are automatically adapted so
that the control behavior does not change.
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
List of signals for analog outputs
Parameter
r0060
r0061
r0063
r0066
r0068
r0070
r0079
r0082
r0064
r0074
r0077
r0078
r0083
r0084
r1480
r1482
Basic information about the drive system
12.4 BICO technology: interconnecting signals
Unit
Scaling
(100% = ...)
rpm
p2000
rpm
p2000
rpm
p2000
Hz
Reference frequency
Arms
p2002
V
p2001
Nm
p2003
kW
r2004
rpm
p2000
%
Reference modulation depth
A
p2002
A
p2002
%
Reference flux
%
Reference flux
Nm
p2003
Nm
p2003
855