5. Select the drive object in the "DO" drop-down list.
Figure 6-37
6. Enter the parameter of the drive object in the following input fields (e.g. 601:0).
7. Click the "ADD" button in the parameter list to the right of the first free line.
8. Repeat steps 5 to 7 for each drive object that you want to create in the parameter list.
9. Then click the "Save List" button to save the parameter list to the memory card of the
10. If you want to change the order of the parameter lists, move the parameter list (tab) to the
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Drive parameters - specifying the parameter list
– First field: Parameter number
– Second field: Index
– Third field: Bit number
The parameter name is now displayed on the right of the input fields. If no index and no
bit number has been entered, the fields remain empty.
The parameter is now inserted in the parameter list.
drive (OEM/SINAMICS/HMI/PARLISTS).
A new tab is created for the new parameter list. The name of the parameter list appears
in the tab. You can view the actual parameter values and change them when required via
this tab.
desired position using drag and drop or with the aid of the "UP" and "DOWN" buttons.
Basic functions