Know-How Protection - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Deactivating write protection
1. Connect the Control Unit to the programming device.
2. Call STARTER.
3. Download your project.
4. Establish a connection to the target device.
5. Select the required drive unit in the project navigator of your STARTER project.
6. Call the shortcut menu "Write protection drive unit > Deactivate".
Parameters without write protection
Certain parameters are excluded from the write protection in order not to restrict the
functionality and operability of the drives. The list of these parameters can be found in the
SINAMICS S120/150 List Manual in Section "Parameters for write protection and know-how
protection", Subsection "Parameters with WRITE_NO_LOCK".
The "Restore factory settings" function can also be used when write protection is activated.
12.14.2

Know-how protection

The "Know-how protection" function prevents, for example, strictly confidential company
know-how for configuration and parameter assignment from being read by unauthorized
persons.
The know-how protection requires a password. The password must comprise at least 1 and
a maximum of 30 characters.
Note
Password security
You are responsible for the security of your password. Whenever possible, use a password
with sufficient length (min. eight characters); use upper- and lower-case letters and special
characters.
The know-how protection is a pure online function. Therefore, establish a direct connection
to the Control Unit before setting the password.
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
The hatching in the expert list disappears after deactivation. The parameters can be set
again.
Basic information about the drive system
12.14 Write and know-how protection
927