Siemens SINAMICS S120 Function Manual page 663

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Bit
Meaning
Note:
The message is parameterized as follows:
p2141 Threshold value
p2142 Hysteresis
11
I, M or P limit reached or exceeded
12
Holding brake open
13
No motor overtemperature alarm
14
Reserved
15
Reserved
ZSW2_BM (status word 2, metal industry)
See function diagram [2429].
Table 10- 27 Description of ZSW2_BM (status word 2, metal industry)
Bit
Meaning
0
Reserved
1
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Alarm class bit 0
6
Alarm class bit 1
7
Reserved
8
Reserved
9
Limit speed setpoint
10
Upper torque limit
11
Lower torque limit
12
Reserved
13
Safe Stop 1
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Remarks
1
I, M or P limit not reached
0
I, M or P limit reached or exceeded
1
Holding brake opened
0
Holding brake closed
1
Motor overtemperature alarm not active
0
Motor overtemperature alarm active
-
-
-
-
Remarks
-
-
-
-
-
-
-
-
-
-
-
Bits 5-6: Alarm stage of SINAMICS drives,
transferred as attribute in alarm message
-
value = 0: Alarm (previous alarm stage)
value = 1: Alarm class A
value = 2: Alarm class B
value = 3: Alarm class C
-
-
-
-
1
Speed setpoint limited
0
Speed setpoint not limited
1
Upper torque limit reached
0
Upper torque limit not reached
1
Lower torque limit reached
0
Lower torque limit not reached
-
-
1
Normalized signal according to PROFIdrive on
PROFIsafe
10.1 Communication according to PROFIdrive
Communication
Parameter
BO: r1407.7
BO: r0899.12
BO: r2135.14
-
-
Parameter
-
-
-
-
-
BO: r2139.11
BO: r2139.12
-
-
r1407.11
r1407.8
r1407.9
-
r9773.2
661