6.12

Motor Module as a Braking Module

This function uses a Motor Module as a Braking Module. To do this, three resistors are
connected to the Motor Module instead of a motor.
Requirements for operation as a Braking Module:
● Three identical braking resistors in a star (see table below) or delta connection
● At least 10 m cable length to the resistors
● Configuration in STARTER
Note
This function is released for:
• SINAMICS S120 Motor Modules Cabinet
• SINAMICS S120 Motor Modules Chassis (500 V - 690 V)
• SINAMICS S120 Motor Modules Chassis (380 V - 480 V) > 250 kW
• SINAMICS S120 Motor Modules Chassis Liquid Cooled (380 V - 480 V) > 250 kW
• SINAMICS S120 Motor Modules Chassis Liquid Cooled (500 V - 690 V)
6.12.1

Features

● Three identical resistors required
● Parallel connection of Motor Modules possible
● Integrated protective devices are available for monitoring the resistors
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
– VECTOR drive object
– V/f control
6.12 Motor Module as a Braking Module