Extended Monitoring Functions - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Function modules

7.2 Extended monitoring functions

7.2
Extended monitoring functions
When the extension is activated, the monitoring functions are extended as follows:
● Speed setpoint monitoring: |n_set| ≤ p2161
● Speed setpoint monitoring: n_set > 0
● Load monitoring
Load monitoring
This function monitors power transmission between the motor and the working machine.
Typical applications include V-belts, flat belts, or chains that loop around the belt pulleys or
cog wheels for drive and outgoing shafts and transfer the peripheral speeds and forces. The
load monitoring can identify blockages in the working machine and interruptions to the power
transmission.
During load monitoring, the current speed/torque curve is compared with the programmed
speed/torque curve (p2182 to p2190). If the actual value is outside the programmed
tolerance bandwidth, a fault or alarm is triggered depending on parameter p2181. Faults or
alarms can be delayed using parameter p2192 to prevent false messages caused by brief
transitional states.
Figure 7-3
414
Load monitoring
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3