Basic Infeed - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

1.3

Basic Infeed

Features
● For Basic Line Modules chassis and booksize
● Unregulated DC-link voltage
● Control of external braking resistors with 20 kW and 40 kW Basic Line Modules (with
Description
The Basic Infeed open-loop control can be used to switch on/off the Basic Line Module. The
Basic Line Module is an unregulated infeed unit without regenerative feedback capability.
The open-loop control firmware for the Basic Line Module is on the assigned Control Unit.
The Basic Line Module and Control Unit communicate via DRIVE-CLiQ.
Figure 1-7
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
temperature monitoring)
Schematic structure of Basic Infeed booksize
Infeed
1.3 Basic Infeed
47