003-332 IISS-ESS Communication 13 RAP
BSD-ON:3.1/6.2
The NAK that notifies of the occurrence of a transmission failure is received. (The Check Code
of the received Message Packet is incorrect.)
Procedure
Disconnect and reconnect the IIT/IPS PWB Harness.
Reload Software (ADJ 9.3.1).
If the problem persists, replace the IIT/IPS PWB (PL 13.3).
Status-indicator-raps
003-332, 003-333
003-333 IISS-ESS Communication 14 RAP
BSD-ON:3.1/6.2
The NAK that notifies of the occurrence of a transmission failure is received. (A parity error was
detected by hardware of the UART.)
Procedure
Disconnect and reconnect the IIT/IPS PWB Harness.
Reload Software (ADJ 9.3.1).
If the problem persists, replace the IIT/IPS PWB (PL 13.3).