Xerox WorkCentre 7132 Service Documentation page 118

Service manual
Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

A
B
Measure the voltage between the DADF PWB P761-12 (+) and GND (-) (BSD 5.4 Flag
4). The voltage is approx. +5VDC.
Y
N
Replace the DADF PWB (PL 16.3).
Measure the voltage between the DADF PWB P761-11 (+) and GND (-) (BSD 5.4 Flag
3).Actuate the DADF Pre Registration Sensor with paper. The voltage changes.
Y
N
Replace the DADF Pre Registration Sensor (PL 16.7).
Replace the DADF PWB (PL 16.3).
Replace the DADF PWB (PL 16.3).
Revision
WorkCentre 7132
005-301 DADF Top Cover Open
Detected the DADF Top Cover Opened.
Procedure
To check the Top Cover is Latched. Check the connections between the Top Cover Interlock
Switch and the DADF PWB. If OK, replace the Top Cover Interlock Switch. If the problem per-
sists, replace the DADF PWB (PL 16.3).
January 2007
2-95
Status-indicator-raps
005-286, 005-301

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents