003-322 IISS-ESS Communication 3 RAP
BSD-ON:3.1/6.2
The ACK (acknowledgement code) could not be received after 2 resend attempts. (The Packet
No. of the sent Message Packet is incorrect.)
Procedure
Disconnect and reconnect the IIT/IPS PWB Harness.
Reload Software (ADJ 9.3.1).
If the problem persists, replace the IIT/IPS PWB (PL 13.3).
Revision
WorkCentre 7132
003-323 IISS-ESS Communication 4 RAP
BSD-ON:3.1/6.2
The ACK (acknowledgement code) could not be received after 2 resend attempts. (The Mes-
sage Length of the sent Message Packet is incorrect.)
Procedure
Disconnect and reconnect the IIT/IPS PWB Harness.
Reload Software (ADJ 9.3.1).
If the problem persists, replace the IIT/IPS PWB (PL 13.3).