Retrieve Commands

Retrieve Reference Parameter

The Retrieve Reference Parameter command reports which input port is the current
reference input.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
Response Format
Example Command
Example Response

Retrieve SQL Parameter

The Retrieve SQL Parameter command reports the Synchronization Quality Level
(SQL) and the mode of operation for the specified input port.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
410 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
RTRV-PRMTR-REF:[tid]::ctag;
none
2
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^aid:mode,as,ar<cr><lf>
where:
mode is PRI|SSM|Best
as and ar indicate if AutoSwitch and AutoReturn are On or
Off, respectively
RTRV-PRMTR-REF:TSG::ctag;
TSG 02-09-10 19:00:19
M 13 COMPLD
^^^INP2:PRI,On,Off
;
RTRV-PRMTR-REF:[tid]:[aid]:ctag;
INP, INPx, INPx[-y], ALL, <null>
2
12778474-002-2 Revision F – March 2004