Retrieve Input Condition; Retrieve Configuration - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Minimum User Level
Example Command
Example Response

Retrieve Input Condition

The Retrieve Input Condition command displays the current operating mode and
status of the selected input ports.
If the TSG-3800successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Response Format
Valid aid
Minimum User Level
Example Command
Example Response

Retrieve Configuration

The Retrieve Configuration command reports configuration (inventory
management) information for the specified module.
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
2
RTRV-COND-EQPT:TSG:ALL;
TSG 10-05-15 13:17:40
M 1 COMPLD
"CPU:Run,OK"
"ClkA:Lock,OK"
"ClkB:Lock,Ref"
"FGA:Auto,OK"
"FGB:Auto,Ref"
;
RTRV-COND-INP:[tid]:[aid]:ctag;
^^^aid:mode,status<cr><lf>
where Mode is Ref|OK|Mon|Dis
and Status is OK|Alrm|Fail
INP, INPx, INPx[-y], ALL, <null>
2
RTRV-COND-INP:TSG:INP3;
TSG 10-05-15 13:17:40
M 1 COMPLD
"INP3-1:Ref,OK"
"INP3-2:OK,OK"
"INP3-3:Mon,OK"
;
TL1 Reference
Retrieve Commands
TSG-3800 User's Guide 391

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsg-3800Tsg-3800xTsg-3800eTsg-3800ex

Table of Contents