Table B-4. Time Constant Values for Each Type of Clock Module
Type
Stratum 2 Rb
100
Stratum 2.0 DDS
50
Stratum 2.0
50
Stratum 2.1 DDS
50
Stratum 2.1
50
Stratum 3E
20
Communication Command
This command allows you to display and modify the parameters that affect the
EIA-232 ports on the TSG-3800.
Level 0
Not applicable
Level 1
COMM [A|B] [BAUD|ECHO|EOL|HAND|MODE|TIMEOUT]
Displays the values for each parameter
Level 2
COMM [A|B] BAUD [300|1200|2400|4800|9600|19200]
COMM [A|B] ECHO [OFF|ON]
COMM [A|B] EOL [LF|CR|CRLF]
COMM [A|B] HANDSHAKE [OFF|HARDWARE|SOFTWARE]
COMM [A|B|TELNET|BINARY] TIMEOUT [5 - 43200]
All values set at this level revert to default/stored values at logoff.
where:
Baud is the baud rate of the port (default = 9600)
Echo is used for full/half duplex operation (default = On)
EOL sets the End of Line termination (default = CRLF)
Handshake determines the method of connection (default = Off)
Timeout sets the length of inactive time before automatically logging off the
user (default = 300)
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Starting TC
Minimum TC
500
100
100
100
100
20
System Administrator's Reference
Command Reference
Maximum TC
Pull-in Range
10000
+5.76 x 10E
5000
+5.76 x 10E
5000
+5.76 x 10E
5000
+5.76 x 10E
5000
+5.76 x 10E
1000
+1.6 x 10E
TSG-3800 User's Guide 343
–8
–8
–8
–8
–8
–5