Table 7-6
describes the front panel status indicators (LEDs) on the AMI 10-Output
module.
Table 7-6. AMI 10-Output Module Indicators
Indicator
POWER
INPUT
FAULT A
INPUT
FAULT B
OUTPUT
FAULT

Functional Description

Refer to
Figure 7-4
be connected to the module, depending upon the Frame Generator settings in the
TSG-3800. Each pair consists of A and B signals, coming from Frame Generator A
and Frame Generator B, respectively. The A and B inputs are identical signals
providing redundant input signals to the AMI 10-Output module.
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Color
Green
On = Module is receiving power.
Off = Module is not receiving power.
Amber
On = No reference signal at input A, or failure of
module input buffers.
Off = Reference signal at input A.
Amber
On = No reference signal at input B, or failure of
module input buffers.
Off = Reference signal at input B.
Red
On = Output failure (one or more).
Off = All outputs available.
for the following functional discussion. Two pairs of inputs can
Output Modules
AMI 10-Output Module
Description