Frame Generator Jumper Settings; T1/E1 Frame Generator S1 And S2 Rocker Settings - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Configuring the Frame Generator Module
For proper operation of the ESF/D4 10-Output module with the Frame Generator
(06568-501 or 23476568-xxx-0), the jumpers on the Frame Generator must be
configured as shown in
Table 7-14. Frame Generator Jumper Settings
Terminal Block
TB1
TB2
Configuring the T1/E1 Frame Generator
The rocker switches and jumpers on the T1/E1 Frame Generator Module
(23478305-xxx-0), or T1/E1 SSM Frame Generator Module (23478443-xxx-0) must
be set as shown
Set jumper W9 to the 1.544 MHz position to provide a 1.544 MHz clock at CLK1.
Jumper W10 may be set as desired.
Set S1 and S2 as shown in
both sides of the switch block (1 through 6). A switch is OFF when the left side of
the rocker is pressed down. A switch is ON when the right side of the rocker is
pressed down.
Table 7-15. T1/E1 Frame Generator S1 and S2 Rocker Settings
Switch
1
2,3,4,5,6
1,2,3
4
5
6
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table
7-14.
Setting
A-B
Select ESF Framing
B-C
Select 1.544 MHz Clock
Table 7-15
for the ESF/D4 10-Output module to function properly.
Table
7-15. The number of each rocker is located on
Setting
Switch S1
ON (required)
(Not used by ESF/D4 Output
Module. Settings are optional.)
Switch S2
(Not used by ESF/D4 Output
module. Settings are optional.)
(Rocker not used)
OFF (required)
OFF or ON
ESF/D4 10-Output Module
Function
Function
Sets Output 1 for T1
(Refer to Frame Generator section)
(Refer to Frame Generator section)
NA
Selects ESF Framing
Enable/Disable BOM
TSG-3800 User's Guide 227