Table 3-7. Default Hardware Configuration
Jumper/Switch
HARDWARE PROVISIONS (X-Port Input Module, P/N 23478303-00x-0)
W11 Port 1
W10 Port 2
W9 Port 3
HARDWARE PROVISIONS (CPU Module, P/N 23478301-00x-0)
W14 & W15
W13 & W16
W7 & W8
W9 & W11
Note: The jumper settings shown for the CPU configure COMM A and COMM B for connection to a
PC. Refer to
Configuring the CPU
connections.
HARDWARE PROVISIONS (Frame Generator Module, P/N 23478443-000-0)
Clock Frequency Selection
W9 CLK1
W10 CLK2
Switch Block S3
Rocker 1
Rocker 2
Rocker 3
Note: S3 selects the bit position for insertion of SSM for E1 signals.
Switch Block S2
Rocker 1 (E1 only)
Rocker 2 (E1 only)
Rocker 3 (E1 only)
Rocker 4
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Factory Default
(1-2)
(2-3) 20 dB amplification
No amplification
(1-2)
(2-3) 20 dB amplification
No amplification
(1-2)
(2-3) 20 dB amplification
No amplification
(1-2) and (3-4)
(3-4)
(1-2)
(4-6)
Module, on page 175 for proper settings for MAC or Modem
1.544 MHz
1.544 MHz/2048 MHz/8 kHz
2.048 MHz
1.544 MHz/2048 MHz/8 kHz
OFF
Option shown is Bit #4
OFF
ON
ON
On = Disable CRC4
Off = Enable CRC4
ON
On = Select CAS signaling
Off = Select CCS signaling
ON
On = Select AMI encoding
Off = Select HDB3 encoding
Not Used
Operating the TSG-3800
Default Parameter Values
Options
User Settings
TSG-3800 User's Guide 111