TL1 Reference
Set Commands
Set Clock
The Clock Parameter command sets the operating mode of the specified Clock
module, as well as the tau (time constant), AutoReturn mode, and the Control
Value. The mode must be set to Hold in order to set the CV. Null values leave the
settings for parameters unchanged.
When the TSG-3800 successfully receives the command and the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
Valid aid
Minimum User Level
Example Command
Example Response
Set Delay
The Set Delay Parameter command defines the length of time (in seconds) before a
change in the SSM appears on the outputs. The delay can be from 1 to 30 seconds.
When the TSG-3800 successfully receives the command and the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
Valid aid
Minimum User Level
Example Command
Example Response
384 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
SET-PRMTR-CLK:[tid]:[aid]:ctag::mode[,tau
[,ar[,cv]]];
CLKA, CLKB
mode = Warm, Hold, Acq, Lock, <null>
tau = Min, Max, <number>, or <null>
AR = On, Off, or <null>
CV = <number> or <null>
2
SET-PRMTR-CLK:TSG3800::ctag:Lock;
TSG3800 02-09-11 09:48:11
M 627 COMPLD
;
SET-PRMTR-DELAY:[tid]::ctag::delay;
none
delay = 1 to 30
2
SET-PRMTR-DELAY:TSG3800::ctag:5;
TSG3800 02-09-11 09:48:37
M 628 COMPLD
;
12778474-002-2 Revision F – March 2004