Set AutoSwitch
The AutoSwitch Parameter command turns the input reference AutoSwitch
parameter on or off.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
Example Command
Example Response
Set Error
The Error Parameter command sets the specified error parameter (AIS, BPV, CRC,
LOS, or OOF) for the specified input. The specified error condition (Fail, Alarm,
Report, or Ignore) is reported when the condition is present for the specified time
period (ercnt); the condition clears when the condition has no longer been present
for the specified time period (clcnt).
When the TSG-3800 successfully receives the command and the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
Valid aid
Minimum User Level
Example Command
Example Response
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
SET-PRMTR-AS:tid::ctag::mode;
none required
mode = On or Off
2
SET-PRMTR-AS:TSG3800::ctag::ON;
TSG3800 02-09-11 09:45:45
M 623 COMPLD
;
SET-PRMTR-AIS:tid:[aid]:ctag:ercnt,clcnt:mode;
SET-PRMTR-BPV:tid:[aid]:ctag:ercnt,clcnt:mode;
SET-PRMTR-CRC:tid:[aid]:ctag:ercnt,clcnt:mode;
SET-PRMTR-LOS:tid:[aid]:ctag:ercnt,clcnt:mode;
SET-PRMTR-OOF:tid:[aid]:ctag:ercnt,clcnt:mode;
INP, INPx, INPx[-y], ALL, null
ercnt, clcnt = 0-100000 (seconds)
mode = Fail, Alrm, Rept, Ignr
2
SET-PRMTR-AIS:TSG3800::ctag:25:15:Alrm;
TSG3800 02-09-11 09:47:33
M 626 COMPLD
;
TL1 Reference
Set Commands
TSG-3800 User's Guide 383