Viewing Phase Measurements - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Display: TSG->INPUT 4.1 AIS ZERO
«date» «time» «oper» zeroed AIS error counter for «input»
TSG->

Viewing Phase Measurements

The TSG-3800 measures the phase between each input and each clock. You can
display:
The most recent phase measurement for all inputs
Up to the last one hundred 1-second interval phase readings between the clocks
and a specified input
Up to the last one thousand 100-second average phase readings (27 hours)
between the clocks and a specified input
The readings are displayed in nanoseconds (chronological).
To view the most recent phase measurements for all inputs, type:
then press Enter
PHASE
A typical response from the TSG-3800 is:
->PHASE
The Current Time is 20JUN2004 08:32:01.122
The Phase (1 sec) for Inp1.1 is
The Phase (1 sec) for Inp1.2 is
The Phase (1 sec) for Inp1.3 is
The Phase (1 sec) for Inp2.1 is
The Phase (1 sec) for Inp3.1 is
The Phase (1 sec) for Inp3.2 is
The Phase (1 sec) for Inp3.3 is
The Phase (1 sec) for Inp4.1 is
->
To display the last n phase readings on a specified input, type:
PHASE «input» [T1|T100] «n»
where «input» is described in
selected reference)
T1 is 1-s averages (default) T100 is 100-s averages
«n» is 1 to 100 for 1-s averages and 1 to 1000 for 100-s
averages.
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
System Administrator's Reference
Provisioning Input Reference Signals
0
0
0
0
0
0
1
0
0
-1
0
0
-12
0
0
0
then press Enter
Table B-3
(default is the
TSG-3800 User's Guide 333

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsg-3800Tsg-3800xTsg-3800eTsg-3800ex

Table of Contents