Set Commands
Minimum User Level
Example Command
Example Response
Related Command

Set Enable

The Set Enable command enables the specified Clock module, Frame Generator
module, Input module, or input port. The TL1_SECU aid sets the security mode for
TL1 connections; users must use a valid user name and password to log in.
When the TSG-3800 successfully receives the command and if the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
Valid aid
Minimum User Level
Example Command
Example Response

Set Event

The Set Event command sets the event-reporting mode
When the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
380 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
2
SET-DIS:TSG:CLKA:ctag;
TSG 02-05-16 15:02:19
M 11 COMPLD
;
SET-EN
SET-ENA:[tid]:[aid]:ctag::;
CLKx, FGx, INPx, INPx[-y], TL1_SECU
2
4 to set TL1-SECU
SET-ENA:TSG:INP3-1:ctag;
TSG 02-05-16 13:46:16
M 1 COMPLD
;
SET-EVNT:[tid]::ctag::mode;
none
mode = NONE, INP, EQPT, ALRM, ALL