Stratum 3E Quartz Clock Module Specifications - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

CPU, Frame Generator, and Clock Modules
Clock Module
Table 6-8. Stratum 2E Rubidium Clock Module Specifications (Continued)
Signal Characteristic
Wander Output(Locked or
Holdover)MTIE and TDEV
Jitter Output (Locked or Holdover)
Operating Temperature Range
Storage Temperature Range
Time Constant Range
Table 6-9. Stratum 3E Quartz Clock Module Specifications
Signal Characteristic
Accuracy (Free Running)
Stability (Holdover)
±
0 to 24 hrs @ 25° C
15°C
0 to 24 hrs 0 to 50°C
Pull-In Range (Acquire Mode)
Tuning Resolution (Locked Mode)
Warm-Up Time (Warmup Mode)
Acquisition Time (Acquire Mode)
Wander Output
(Locked or Holdover)
MTIE and TDEV
Jitter Output (Locked or Holdover)
Operating Temperature Range
Storage Temperature Range
Time Constant Range
182 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Specification
Includes effects of all TSG modules:Exceeds
requirements of T1.101-1999, GR-378-Core,
GR1244-Core, ETS 300 462, and ITU G.812.
< 0.01 UI
–5° to 50°C
–40° to 70°C
500 to 10000 seconds
Specification
±
–7
1.8 x 10E
per year
±
–6
3 x 10E
per 20 years
±
–9
5 x 10E
±
–8
1 x 10E
±
–5
1.65 x 10E
–12
2.2 x 10E
15 minutes
1 hour to enter Locked Mode
Includes effects of all TSG modules:
Exceeds requirements of T1.101-1999, GR-378-Core,
GR1244-Core, ETS 300 462, and ITU G.812.
< 0.01 UI
0° to 50°C
–40° to 70°C
25 to 300 seconds
12778474-002-2 Revision F – March 2004