Table 7-53. Timing Insertion Module Specifications (Continued)
Signal Characteristic
Overshoot (at 0' LBO)
Jitter
Drive Capability
Termination Impedance
Line Build Out
Passive bypass capability
Output on LOS or OOF
Major Faults
Programmable Faults

Configuring the Timing Insertion Module

This section describes how to configure the Timing Insertion module to meet the
requirements of your particular installation.
Caution: To prevent ESD damage to the module, always observe the
precautions described in
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
10% of peak to base amplitude
< 0.03 UI
0 to 655 feet, 22AWG ABAM cable
100 Ω ±5%
0-655 ft. in 4 steps
Relay bypasses module on fault
AIS or framed all ONEs (switch selectable)
Alarm Conditions
Loss of (or fault in) both clock feeds
Failure of both Clock Modules
Module failure
LOS or OOF on input to TIM
SLIP (Major/Minor/Ignored)
Properly Handling the
Timing Insertion Module
Specification
Modules, on page 61.
TSG-3800 User's Guide 283
Output Modules