Set Commands; Set Clock; Alarm Codes - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

TL1 Reference

Set Commands

If the date is null but is followed by a time, the date is the current date. If the start or
stop time is null but is preceded by a date, the time is the current time. If the start
date and time is null, then the start date and time is the start of data. If the stop date
and time is null, then the stop date and time is the end of data. The comma must be
present to indicate a null start.
<almcde> reports the level of the alarm, as described in
Table C-5. Alarm Codes
Alarm Code
*C
**
*^
A^
<atag> is a six-digit correlation tag that increments with every message the
TSG-3800 sends.
<mod1> is either ALRM or EVNT
<mod2> is INP (T1 for the SBC software) for input signal faults, OPT for output
signal faults, or EQPT for other faults.
Set Commands
Each Set command you submit causes the TSG-3800 to respond with the Complied
message.
Valid <tid> code: the assigned tid (see SET-TID; the default TID is TSG) or null. If
null, the TSG-3800 requires the <aid>.
Valid <aid> code:
Null (no characters). If null, the TSG-3800 requires the <tid>
ID00000

Set Clock

The Set Clock command changes the current output clock to the clock specified by
the aid. If the aid is invalid, if the clock is not available, or if the AutoReturn is set to
On, the TSG-3800 returns the DENY message.
378 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Type of Alarm
Critical
Major
Minor
Non-alarm event
Table
C-5.
12778474-002-2 Revision F – March 2004