Output Modules
Output Fault Analyzer
Figure 7-28. Functional Block Diagram

Specifications

The specifications for the Output Fault Analyzer are listed in
Table 7-58. Specifications
Signal Type
DS1 (1.544 MBPS) AMI
CC (64/8 kHz) AMI
Input Signal Frequency
The Analyzer operates on DS1 or Composite Clock Alternate Mark Inversion
signals; change between input signals is automatic.
290 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Expected Level
2.4 to 3.6 Vp (3.0 Vp nominal)
2.7 to 5.5 Vp (3.5 Vp nominal)
12778474-002-2 Revision F – March 2004
Table
7-58.
Fault Threshold
2.0 V ±10%
2.0 V ±10%