Functional Description; Ami 20-Output Module; Ami 20-Output Module Status Indicators - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Table 7-1
describes the AMI 20-Output module front panel status indicators (LEDs).
Table 7-1. AMI 20-Output Module Status Indicators
Indicator
POWER
Green
INPUT A
Amber
INPUT
Amber
FAULT B
OUTPUT
Red
FAULT

Functional Description

Refer to
Figure 7-2
be connected to the module, depending upon the Frame Generator settings in the
TSG-3800. Each pair consists of A and B signals, coming from Frame Generator A
and Frame Generator B, respectively. The A and B inputs are identical signals
providing redundant input signals to the AMI 20-Output module.
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Color
On = Module is receiving power.
Off = Module is not receiving power.
On = No reference signal at input A, or failure of
module input buffers.
Off = Reference signal at input A.
On = No reference signal at input B, or failure of
module input buffers.
Off = Reference signal at input B.
On = Output failure (one or more).
Off = All outputs available.
for the following functional discussion. Two pairs of inputs can

AMI 20-Output Module

Description
TSG-3800 User's Guide 207
Output Modules

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsg-3800Tsg-3800xTsg-3800eTsg-3800ex

Table of Contents