Event Listing - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

ALARM(CPU alarm operation)
OPER, MSG (operator setting/ message)
Abbreviations:
SSMSync Status Message (E1) or Bit-Oriented Message (T1)
SQLSync Quality Level
Table B-5. Event Listing
Event
Type
No.
1
Equipment,
Minor, Intifcfail
2
Equipment,
Event,
Restored
3
Message,
Event, Added
4
Message,
Minor,
Removed
5
Message,
Event, Oper
6
Message,
Event, Oper
7
Message,
Event, Oper
8
Input, Minor,
SQL
9
Equipment,
Event, Msg
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
Local 1 PPS
Occurs when the 1 PPS signal from the CPU's
Failed
internal clock is too far off frequency to lock to. This
normally indicates that the CPU module needs
servicing.
Local 1 PPS
Occurs when the 1 PPS signal from the CPU's
Restored
internal clock has stabilized when it had previously
failed.
Module
Occurs when a new module is added to the system. It
Added
gives the slot and the module type.
Module
Occurs when an module is removed from the system.
Removed
It will also occur if power is lost on the module.
User Set
Signals that the operator has set the provisioned input
Priority
priority for the given port.
User Set SSM
Signals that the operator has set the provisioned input
Alarm Mode
priority alarm mode for the given port.
User Set
This event signals that the operator has set the SSM
Input SSM
selection mode for the output SSM.
Selection
Mode
Clock SQL is
This event signals that the Clock module SQL is
Better Than
better than the SQL of the input reference. This event
Input
will not occur in Ensemble Mode.
Reference
SQL
Non-Volatile
This event occurs during bootup and signals that the
Clock
time stored in the battery-backed clock is not
Initialized
operating.
System Administrator's Reference