TL1 Reference
Set Commands
Example Command
Example Response

Set MTIE

The Set MTIE Parameter command sets the input MTIE stability thresholds for the
specified input. The threshold settings lim1 and lim2 are values in ps/s. The error
mode mod1 and mod2 determine what happens when lim1 and lim2 are exceeded,
respectively. The tmper determines which time period the thresholds and error
conditions apply to. Use aid ALL or <null> to specify all inputs.
When the TSG-3800 successfully receives the command and the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
Valid aid
Minimum User Level
Example Command
Example Response

Set Priority

The Set Priority Parameter command provisions the specified input port at the
selected priority level. Use aid ALL to specify all inputs.
When the TSG-3800 successfully receives the command and the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Command Syntax
Valid aid
386 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
SET-PRMTR-INPT:TSG3800:INP3-3:ctag:D4,On,On,2
.048,75;
TSG3800 02-09-11 09:49:29
M 631 COMPLD
;
SET-PRMTR-MTIE:[tid]:[aid]:ctag::lim1,mod1,li
m2,mod2, tmper;
INP, INPx, INPx[-y], ALL, <null>
lim1, lim2 = <number>
mod1, mod2 = Fail, Alrm, Rept, Ignr
tmper = 100, 1000, 10000
2
SET-PRMTR-MTIE:TSG3800:INP1:ctag:175,Alrm,200
,Fail,1000;
TSG3800 02-09-11 09:56:01
M 655 COMPLD
;
SET-PRMTR-PRI:[tid]:[aid]:ctag:priority;
INPx, INPx[-y], ALL
priority = 0, 1, 2, 3, 4
12778474-002-2 Revision F – March 2004