Retrieve PM Phase

The Retrieve PM Phase command reports the phase data stored in the 1-s or 100-s
phase history buffers for the specified port. You can also specify the number of data
points to display.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
Valid aid
Minimum User Level
Response Format
Example Command
Example Response
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
RTRV-PM-PHA:[tid]:[aid]:ctag[::tmper][:points
]];
where:
tmper is 1 or 100
points is 1–100 for tmper = 1 and 1–1000 for tmper = 100.
Default is 1
INPx[-y]
1
<cr><lf><lf>
M^ctag^COMPLD<cr><lf>
^^^"aid:ocrdat,ocrtim,PHA,tmper,(monval1),
(monval2)[<cr><lf>
;
where:
ocrdat and ocrtime are the actual date and time the data
were collected
PHA describes the data that follows
tmper is the data measurement time period in seconds
monval1 and monval2 are the phase values for the
specified input port in nanoseconds
RTRV-PM-PHA:TSG:INP1:ctag;
TSG 02-09-10 19:00:19