Operating the TSG-3800

Default Parameter Values

Restarting the TSG-3800

You can restart the TSG-3800 and reset it to the default settings using the Restart
command. When restarted, the Clock modules cycle through the Acquire and
Locked operating modes again. This command has the same effect as powering
down and re-applying power to the shelf.
Caution: The RESTART command causes the processor to execute
the self-test routine. The self-test routine erases measurement history
and clears all disabled or failed modules.
To restart the TSG-3800, type:
RESTART
Default Parameter Values
This section describes the factory default values and the range of
3-6
lists the software default settings and
settings. Both tables have a column for entering your own settings.
Table 3-6. Default Software Configuration
Setting
SOFTWARE PROVISIONS (X-Port Input Module, P/N 23478303-00x-0)
Input AUTORETURN
Input AUTOSWITCH
Signal Type
Signal Framing
T1
E1
Input Clock Freq
Zero Suppression ZS
CRC
SSM
Input Termination
MTIE/FREQ Mask
108 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
then press Enter
Factory Default
ON
ON/OFF
ON
ON/OFF
T1
T1/E1/CLOCK
ESF
ESF/D4
CCS
CCS/CAS
1MHz
1/ 1.544/ 2.048/ 5/ 10 MHz
OFF
ON/OFF
OFF
ON/OFF
OFF
ON/OFF
3300
3300/ 120/ 100/ 75/ 50
MCD
PRS/OCN/MCD
Table 3-7
lists the hardware default
Range
12778474-002-2 Revision F – March 2004
selections.Table