T1/E1 Frame Generator Module With Clock Bypass - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

CPU, Frame Generator, and Clock Modules

T1/E1 Frame Generator Module with Clock Bypass

T1/E1 Frame Generator Module with Clock Bypass

The T1/E1 Frame Generator module with Clock Bypass (23478486-000-0)
produces timing signals used by various output modules to create DS1, E1 (CEPT),
and Composite Clock (CC) output signals. The DS1 (ESF only) and E1 signals can
include Synchronization Status Messages (SSM), if required. This module also
provides two clock output signals which can be independently set to 8 kHz,
1.544 MHz, or 2.048 MHz. The front panel is shown in
T1/E1 Frame Generator Module with Clock Bypass
Figure 6-9.
194 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Figure
6-9.
12778474-002-2 Revision F – March 2004