Installing The Cpu Module; Operational Check; Jumper Positions For Different Devices - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

CPU, Frame Generator, and Clock Modules
CPU Module
Table 6-4. Jumper Positions for Different Devices
COMM A
PC
Mac
Modem
COMM B
PC
Mac
Modem
Figure 6-3
illustrates COMM A jumper settings configured for connection to a PC,
and COMM B jumper settings configured for connection to a modem.
Figure 6-3.
Jumper Settings

Installing the CPU Module

The CPU module must be installed in slot 5 of the TSG-3800 main shelf. See
Location and Keyed

Operational Check

Perform the following operational checks after installing the CPU module in the
main shelf. It is assumed that power has been connected to the shelf and is turned
on, and that there is a CPU module installed and functioning properly. A proper
external reference signal must be connected to the corresponding connector on the
rear panel of the main shelf. If used, the fault signal should also be connected to the
main shelf.
176 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
W14
W13
1-2, 3-4
3-4
1-2
1-3, 2-4
7-8
5-6
1-3, 2-4
1-2
3-4
W15
W16
1-2, 3-4
3-4
1-2
1-3, 2-4
7-8
5-6
1-3, 2-4
1-2
3-4
Modules, on page 61.
W7
W11
4-6
1-2
4-6
W8
W9
4-6
1-2
4-6
12778474-002-2 Revision F – March 2004