Retrieving Alarm Data; Resetting Alarms - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Retrieving Alarm Data

The operator can retrieve information concerning alarm status. The response shows
all existing major and minor faults. Use the syntax described in
page 341.
To access the alarm data, type:
ALARM
A typical display is:
+>ALARM
Critical Alarms
None
Major Alarms
None
Minor Alarms
T100 Limit 1 MTIE Alarm on INP4.1
T100 Limit 2 MTIE Alarm on INP4.1
->
Note: Faults can be present with no alarm. This condition exists when
alarms are cleared without fixing the faults. See
page 105, for instructions.

Resetting Alarms

You can reset Audio, Major, Minor, or all alarms using a software command. When
cleared, the appropriate indicators and audio alarms turn off. This action removes
the fault condition. Remaining faults will reactivate the alarm. All faults must be
cleared before an alarm will clear itself. Use the syntax described in
Command, on page 341.
To clear the alarms, type:
ALARM CLEAR CRITICAL|MANJOR|MINOR|AUDIO|ALL
Example
Purpose: Clear all alarms
Command:
ALARM CLEAR ALL
Display:
->ALARM CLEAR ALL
«date» «time» Critical Alarm Cleared
«date» «time» Major Alarm Cleared
«date» «time» Minor Alarm Cleared
+>
12778474-002-2 Revision F – March 2004
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
then press Enter
Operating the TSG-3800
System Commands
Alarm
Command, on
Resetting
Alarms, on
Alarm
then press Enter
TSG-3800 User's Guide 105