Maximum Clock Control Value Ranges - Symmetricom TSG-3800 Series User Manual

Timing signal generator
Table of Contents

Advertisement

Operating the TSG-3800
Provisioning the Clock Modules
Note: The digital control value range is dependent on the clock type.
The range is defined in GR-1244 as 1.2 x (2 x accuracy + pull-in).
Table 3-5. Maximum Clock Control Value Ranges
Clock Type
Stratum 2E Rubidium
Stratum 2 Rubidium
Stratum 2.0 DDS
Stratum 2.1 DDS
Stratum 2.0
Stratum 2.1
Stratum 3E
To display the last n control value readings for the clocks, type:
CLOCK A|B CV T1|T100 {number}
where
{number
Example
Purpose: To display the last three 1-second control voltages.
Command:
CLK CV T1 3
Display:
TSG->CLK CV T1 3
The Control Value for Clk A is 962
The Control Value for Clk A is -28
The Control Value for Clk A is -1021 (49%)
The Control Value for Clk B is -394 (49%)
The Control Value for Clk B is -394 (49%)
The Control Value for Clk B is -394 (49%)
TSG->
100 TSG-3800 User's Guide
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Range
±
4 x 10E
5.76 x 10E
8.95 x 10E
8.95 x 10E
8.95 x 10E
8.95 x 10E
1.65 x 10E
} is the number of readings to display.
–8
–8
–7
–7
–7
–7
–5
then press Enter
(50%)
(49%)
12778474-002-2 Revision F – March 2004

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsg-3800Tsg-3800xTsg-3800eTsg-3800ex

Table of Contents